EK-A150 Wireless HV/LV Remote Phase Detector
EK Instruments EK-A150 — professional wireless hv/lv remote phase detector for industrial electrical testing.
Product Overview
EK-A150 Wireless HV/LV Remote Phase Detector
EK Instruments EK-A150 is a professional wireless hv/lv remote phase detector. Designed for industrial electrical measurement and field testing. Built with precision engineering and reliable components for long-term stability.
Product Function
Applied to phase detection, phase testing, phase sequence judgment, and voltage detection on power lines below 500kV, high-voltage switchgear (metalclad withdraw switchgear, ring main unit, etc.), or substations.
Product Features
1.Adopts wireless transmission technology with a phase detection distance of up to 200 meters, providing accurate phase detection and convenient operation.
2.Voice prompts: "X signal normal," "Y signal normal," "same phase," "out of phase."
3.Equipped with a 3.5-inch LCD color screen that simultaneously displays phase, frequency, phase sequence, and phase detection results, with dynamic vector diagram indication for clear and intuitive viewing.
4.The meter also features voltage detection function and can display the voltage level.
Technical Specification
Power Supply | Host: DC 3.7V, 2500mAh rechargeable lithium battery; Detector: DC 3.7V, 1100mAh rechargeable lithium battery. |
Display Screen | 3.5-inch color screen; display area: 71mm × 53mm. |
Phase Detection Mode | Contact phase detection: when the phase detection voltage is ≤110kV. Non-contact phase detection: when the phase detection voltage is between 10kV and 110kV (phase detection can be performed on the insulation sheath of the cable). When the phase detection voltage exceeds 110kV, non-contact phase detection must be used. |
Phase Detection Voltage | AC 10V~500kV. |
Phase Detection Distance | 200m. |
Phase Qualitative | Same phase: -20°~20°; Out phase: 100°~140° and 220°~260°. |
Phase Range | 0°~360°; Accuracy: ≤±8°; Resolution: 1°. |
Frequency Range | 45.0Hz~65.0Hz; Accuracy: ≤±2Hz; Resolution: 0.1Hz. |
Voltage Detection Indication | "Bee—bee—bee" buzzer sound. |
Voltage Level Display | 0.4kV~110kV. |
Transmitting Frequency | 433MHz. |
Voice Prompts | "X signal normal," "Y signal normal," "same phase," "out of phase." |
Phase Indication | Vector diagram and numerical display simultaneously. |
Data Storage | 200 groups (power down or replacing battery will not lose data). |
Automatic Shut Down | The meter will automatically shut down approximately 15 minutes after startup. |
Battery Level Indication | The host displays battery power in 4 grids. When only 1 grid or 0 grids remain, please charge the battery. When the detector indicator light flashes rapidly, it indicates low battery voltage and the detector needs to be charged. |
Rated Current | Detector: 30mA Max; Host: 150mA Max. |
USB Communication | USB interface; with PC software, stored data can be uploaded to computer for storage, analysis and printing. |
Insulation Rod Length | Telescopic insulation rod: 670mm~3000mm. |
Meter Dimensions | Host: 195mm × 100mm × 45mm; Detector: 130mm × 65mm × 45mm. |
Meter Weight | Approx. 5.66kg (including accessories). |
Insulation Test | The insulation rod stretched to both ends: AC 220kV/rms; Host, detector: AC3700V/rms (between exposed metal and plastic shell). |
Accessories | Host: 1 pc; Detector: 2 pcs; Probe tip: 2 pcs; Probe hook: 2 pcs; Insulation rod: 2 pcs; USB communication/charging cable: 2 pcs; Power adapter: 2 pcs; Test lead: 1 pc; Ring main unit test lead: 2 pcs; Meter case: 1 pc. |
Applications: Power utility, industrial maintenance, electrical testing labs, field engineering services.